Euronda Sanifizer
FAQ

Euronda Sanifizer - FAQ

In this section you can find answers to the most common questions about our disinfectants: from their correct use to certifications, as well as safety and storage.
If you are looking for practical guidelines to choose the right product and use it effectively, you are in the right place: here you will find concrete support so that you can approach daily disinfection with confidence and peace of mind.

MDR certification guarantees even higher quality and safety standards for operators and patients, thanks to tests carried out in certified laboratories, with more stringent requirements than the previous MDD legislation. Choosing an MDR-certified disinfectant or detergent means having full confidence in the effectiveness, efficiency and reliability of the product.

Yes, Euronda Sanifizer disinfectants are more than 90% biodegradable and the formulations are free of EDTA, chlorine, phenols, aldehydes, nanoparticles and CMR. In addition, the Sanifizer Wipes towels are biodegradable and biocompostable. However, after use, they must be disposed of as special waste. Finally, all products in the Sanifizer line are packaged in recyclable packaging and in 30-50% recycled plastic containers.

The entire line is developed according to the philosophy of low dosage: an intelligent formulation that combines synergistic components capable of maximising the effect and effectiveness of cleaning, which minimises the environmental impact thanks to the low concentrations required.

1st generation quaternary ammonium, widely used in the past, is a compound that should be avoided not only because it is sensitising and potentially toxic (including for the environment), but above all because of its low effectiveness on gram-negative bacteria. The introduction and use of 4th generation quaternary ammonia has solved both the problem of toxic and sensitising effects and the low biocidal activity, completing the spectrum of use against gram-negative bacteria too. In addition, 4th generation quaternary ammonium disinfectant products are less volatile.

This type of test simulates the most difficult conditions to ensure maximum bactericidal, yeasticidal/fungicidal, mycobactericidal/tuberculicidal and virucidal effectiveness of the disinfectant in complex clinical situations. Disinfectants are tested on surfaces contaminated with microorganisms in the presence of organic substances that simulate dry organic residue. After the disinfectant is applied, the microbial load reduction is measured. The product is considered effective if it eliminates at least 99.99% of pathogens.

They have a shelf life of up to 3 years from the date of production. A longer shelf life indicates greater stability of the product and guarantees better performance in different conditions of use.

Euronda Sanifizer products are compatible with most materials on the market, including stainless steel, aluminium, zinc, copper, PVC, PPE, PTFE, polystyrene, polycarbonates, PU, rubbers, ceramics, silicone and glass.

No, they are specifically formulated to prevent microfractures and strength reduction in plastic materials, which means they protect tools and surfaces without compromising their own effectiveness. For products that contain alcohol, such as Sanifizer Wipes and Sanifizer Surfaces, the percentage is always less than 50%. This ensures the best ratio between disinfection, drying, and material-protective performance, thanks to the synergistic use with 4th generation quaternary ammonium.

No, Euronda Sanifizer products are safe for operators, as they are non-toxic, free of sensitisers and allergenic perfumes. They do not contain CMR substances (carcinogenic, mutagenic or reprotoxic) and are odourless to avoid allergic reactions. They are not toxic if used properly, but they must not be ingested or applied to the skin.

No, Euronda Sanifizer products are odourless, containing no added fragrances that can cause sensitisation or allergies.

No, they must be stored in a cool place, generally between +5°C and +35°C, and kept in their original container, tightly closed. Particular care is also recommended during transport, especially in the warmer months when temperatures can easily exceed 40°C.

They are ideal for cleaning and disinfecting non-invasive Medical Devices, furniture and equipment.

The towels are 15 x 19 cm in size, the resealable lid keeps them moist at all times and dispenses one towel at a time, reducing the risk of cross-contamination and waste.

No, there is no need to rinse the surface. The low percentage of alcohol in the towels also allows the surface to dry quickly, without deteriorating the material.

4th generation quaternary ammonium (which guarantees the disinfectant effect), chlorhexidine and 16% alcohol.

They are made of high-quality, biodegradable and biocompostable NWF, and soaked in a 90% biodegradable solution. The packaging is made of recyclable PET. After use, they must be disposed of as special waste.

The pH 8.5 enhances the cleansing action, without compromising the integrity of the treated materials.

The towels can also be used on non-immersible rotary instruments, ensuring safe cleaning without corrosive effects.

It is a ready-to-use hydro-alcoholic disinfectant, ideal for cleaning and disinfecting non-invasive Medical Devices, furniture and equipment. It can also be used on dental instruments used during appointments, including burs.
The foaming dispenser reduces waste during application, optimising consumption.

No, there is no need to rinse the surface. The disinfectant dries quickly, leaving no residue.

48% is a balanced percentage that guarantees quick drying and compatibility with materials, avoiding the fixing and corrosive power of alcohols at high concentrations.

Euronda has tested the product on digital screens and dental chairs and proved its effectiveness without corrosive effects.

There are two ways to apply the Sanifizer Surfaces: the direct method, which involves spraying the product directly on the surface to be treated and then wiping with a cloth to spread the product evenly over the surface, and the indirect method: spraying the product first on the cloth and then wiping evenly over the surface to be treated. In both cases, the contact time should always be followed.

Yes, the foaming nozzle allows the product to be dispensed from different angles.

Yes, it is also compatible with submersible rotary instruments and burs, ensuring cleaning and disinfection without causing corrosion.

24 hours in an open container or 72 hours if stored in a closed container, provided it is kept at a stable room temperature.

To obtain a mycobactericidal and tuberculicidal action a dilution of product of 2.5% is necessary. To obtain a bactericidal, fungicidal, yeasticidal, and virucidal action, on the other hand, a low concentration of product (0.5%) and a lower dosage are sufficient.

Eliminates the use of measuring containers, facilitating correct dosing and reducing the risk of assistant error.

Sanifizer Instruments is ideal for manual washing, in decontamination baths and in ultrasonic tanks, acting in just five minutes, ensuring disinfection and cleansing of surgical instruments, endoscopes and Medical Devices.

The 1 L correct dose bottle makes 200 litres of solution.

The immersion time for instruments in Sanifizer Instruments solution varies and depends on the actual needs of the dental office. In general, it ranges from a minimum of 5 minutes to 15 minutes for daily routine activities related to standard instrument reprocessing. The great versatility and compatibility of the product also allow longer contact times, thanks to a completely neutral pH that makes it suitable for almost all materials used in the medical field. A solution that meets the needs and specifications of a modern clinic.

They refer exclusively to the concentrated product. Once diluted, the irritant, corrosive or environmentally hazardous effect ceases.

It is a multi-enzymatic disinfectant and detergent designed for use in synergy with Eurosafe Smart.

It ensures a double action: cleansing thanks to the multi-enzymatic complex and encapsulated enzymes, and disinfecting thanks to the biocidal system that ensures a broad spectrum of action.

It allows a practical and safe replacement of the spent cartridge, improving usability.

The product does not contain chlorine, alcohol, phenols or aldehydes.

Yes, it was developed to be effective in low concentrations (0.5%), it requires a lower dosage, minimising waste and environmental impact. 20 cycles can be performed with just one 1L bottle.

It is a neutralising and cleaning agent for automatic washing systems, ideal in combination with Sanifizer Enzymatic for the operation of Eurosafe 60 or Eurosafe 170.

Removes residual alkalinity, acts as a natural anti-limescale agent and preserves the service life of the instruments.

No, on the contrary, it eliminates residual alkalinity and facilitates drying, reducing the formation of opacity and streaks in surgical instruments and Medical Devices.

It uses lysozyme in combination with protease for deep cleaning and is free of dangerous substances, such as phosphorus and surfactants.

Top